GOLDENGUARD/5000

EMERGENCY HYDRAULIC SYSTEMS & BOP

TECHNICAL DATA
# # # # # # # # #
PART REF. HOSE SIZE R.O.D O.D MAX. W.P BURST MIN. BEND WEIGHT FITTINGS
DN dash inch mm inch mm inch bar psi bar psi mm inch g/m lb/ft Std 1 Std 2
H11020010* 10 -6 3/8” 16.7 0.66 20.7 0.81 345 5,000 1,380 20,010 127 5.00 651 0.44 MF+M00920-06 OPK-06
H11020012* 12 -8 1/2” 20.1 0.79 24.1 0.95 345 5,000 1,380 20,010 150 5.91 820 0.55 MF+M00910-08 OPK-08
H11020016* 16 -10 5/8” 25.5 1.00 30.9 1.22 345 5,000 1,380 20,010 180 7.09 1,490 1.00 IP+M01500-10
H11020019* 19 -12 3/4” 29.0 1.14 36.2 1.43 345 5,000 1,380 20,010 240 9.45 2,024 1.36 IP+M01500-12 SP+M05400-12
H11020025* 25 -16 1” 36.0 1.42 44.0 1.73 345 5,000 1,380 20,010 300 11.81 2,742 1.84 IP+M01500-16 SP+M05400-16
H11020031* 31 -20 1.1/4” 47.0 1.85 55.0 2.17 345 5,000 1,380 20,010 420 16.54 4,293 2.88 IP+M01600-20 SP+M05500-20
H11020038* 28 -24 1.1/2” 54.6 2.15 62.6 2.46 345 5,000 1,380 20,010 500 19.69 5,531 3.72 IP+M01600-24 SP+M05500-24
H11020051* 51 -32 2” 68.4 2.69 76.4 3.01 345 5,000 1,380 20,010 630 24.80 7,712 5.18 IP+M01800-32 SP+M05500-32

KEY FEATURES

• Highly robust hose structure
• Thermal insulation of the hose with a special cover material
• Long lasting resistance of the cover layer
• Cover has flame retardant properties
• High ozone and weather resistance

APPLICATIONS & FLUIDS

• Hydraulics: designed for use in areas where the continuous hydraulic function is required to drive the emergency systems (industrial, marine, off-shore and refineries, defence, mining)
• Flexible hose for hydraulic systems of Blow Out Preventer control lines on drilling rigs
• Mineral oils, glycols and polyglycols, mineral oils in aqueous emulsion

CONTINUOUS SERVICE TEMPERATURE RANGE

-40 °C, -40 °F
121 °C, 250 °F

TUBE

High grade NBR oil resistant synthetic rubber

REINFORCEMENT

Multiple plies of high tensile steel wire spirals (DN 16-25); 2 wire braids (DN 10-12)

COVER

Red insulant and flame retardant synthetic rubber

APPLICABLE SPECS

API 16D Fire Test (pr.10.1.2), DN 10-12: ISO 18752-A; DN 16-51: ISO 18752-C (STD2 fitting) and Type C “Plus” (STD1 fiting), ISO 3862 & SAE J517-100R13 performance

TYPE APPROVALS

DNV-GL; CU-TR; MSHA; API 16D Fire Test (DNV); LR; CCS; ABS

REMARKS

Refer to GoldenGuard assembling instructions and crimp chart for the use of accessories when required:
– STD1 fitting solution: Fire sleeve & metal sleeve over the fitting area required
– STD2 fitting solution: No accessories required
The STD1 fitting solution has been selected for the most demanding applications
DN 10 & 12: Max. continuous temperature 100 °C for these wire braided references