TECHNICAL DATA | |||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
PART REF. | HOSE SIZE | R.O.D | O.D | MAX. W.P | BURST | MIN. BEND | WEIGHT | FITTINGS | |||||||||
DN | dash | inch | mm | inch | mm | inch | bar | psi | bar | psi | mm | inch | g/m | lb/ft | Std 1 | Std 2 | |
H09068008* | 8 | -6 | 5/16" | 15,5 | 0,61 | 35 | 500 | 150 | 2170 | 30 | 1,18 | 165 | 0,11 | OPC-06 | |||
H09068010* | 10 | -8 | 13/32" | 18,0 | 0,71 | 35 | 500 | 150 | 2170 | 50 | 1,97 | 200 | 0,13 | OPC-08 | |||
H09068012* | 13 | -10 | 1/2" | 20,0 | 0,79 | 35 | 500 | 150 | 2170 | 60 | 2,36 | 230 | 0,15 | OPC-10 | |||
H09068016* | 16 | -12 | 5/8" | 23,5 | 0,93 | 35 | 500 | 150 | 2170 | 80 | 3,15 | 295 | 0,20 | OPC-12 |
KEY FEATURES
• Higher compact dimensions within Type A hoses, and outside diameter comparable to reduced barrier hoses
• Low weight
• Easy installation in constrained spaces
• High flexibility and low bend radius
• Low refrigerant permeability and moisture ingression
APPLICATIONS & FLUIDS
• Bus and off-highway equipment air-conditioning systems
• Recommended lubricants: PAG, POE
• Not recommended with refrigerant gases using mineral oils as lubricants
• Refrigerants: R134a; R1234yf
CONTINUOUS SERVICE TEMPERATURE RANGE
-40 °C, -40 °F
125 °C, 257 °F
TUBE
CIIR – Low refrigerant fluid permeability and compatibility with the most common compressor lubricants
REINFORCEMENT
One textile braid
COVER
High temperature and environment resistant synthetic rubber
APPLICABLE SPECS
SAE J3062 Type A Class I; SAE J2064
TYPE APPROVALS
CU-TR
REMARKS
• Guaranteed performance only with Manuli fittings